Mostrar el registro sencillo del ítem

dc.contributor.authorLajara Blesa, Jerónimo
dc.contributor.authorRodríguez Izquierdo, Miguel Ángel
dc.contributor.authorVallés San Leandro, Lorenzo
dc.contributor.authorJutley, Gurjeet
dc.contributor.authorOrtega García, María de los Remedios
dc.contributor.authorZapata Díaz, Juan F.
dc.date.accessioned2024-02-07T15:12:58Z
dc.date.available2024-02-07T15:12:58Z
dc.date.issued2003
dc.identifier.urihttp://hdl.handle.net/10952/7240
dc.description.abstractPURPOSE: To evaluate the visual outcome, light distortion index (LDI), and quality of life (QoL) of patients implanted with two complementary intraocular lenses (IOLs) to treat cataract and presbyopia. METHODS: Twenty-seven consecutive patients with cataract were treated with the implantation of the Artis Symbiose Mid (Mid) IOL (Cristalens Industrie) in the distance-dominant eye and the Artis Symbiose Plus (Plus) IOL (Cristalens Industrie) in the contralateral eye following phacoemulsification. The primary objective was to ascertain the monocular and binocular defocus curves. Secondary endpoints included uncorrected distance visual acuity, corrected distance visual acuity, uncorrected intermediate visual acuity, and distance-corrected intermediate visual acuity at 90 and 70 cm, uncorrected near visual acuity and distance-corrected visual acuity at 40 cm, contrast sensitivity, LDI with a halometer, stereopsis, and patients’ QoL with the validated Visual Function Index (VF-14) questionnaire. These measurements were collected in two visits, at 4.14 ± 3.13 and 10.30 ± 3.14 months postoperatively. RESULTS: Statistically significant differences in the monocular defocus curves were found at the defocus steps of -1.00, -1.25,-1.50, -1.75, -2.50, -2.75, -3.00, -3.50 diopters and the -4.00 diopters (P < .050). The mean binocular defocus curve was 0 logMAR or better from the +0.50 to the -2.50 D defocus steps. Contrast sensitivity was within normal values. The LDI was 12.57 (6.61)% for the Mid eyes, 14.99 ± 5.70% for the Plus eyes, and 10.36 ±4.42% binocularly. The patients’ stereopsis was 40.0 (12.5) arcseconds. The QoL score was 95.99 (7.14) at 10 months. CONCLUSIONS: The implantation of the Artis Symbiose IOLs was a safe and effective treatment for presbyopia compensation in patients with cataract. Both IOLs are complementary and may produce a binocular depth-of-field of 3.00 diopters over 0 logMAR when used together.es
dc.language.isoenes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleStandard Clinical Outcomes, Light Distortion, Stereopsis, and a Quality-of-Life Assessment of a New Binocular System of Complementary IOLses
dc.typearticlees
dc.rights.accessRightsopenAccesses
dc.journal.titleJournal of Refractive Surgeryes
dc.volume.number39es
dc.issue.number10es
dc.description.disciplineMedicinaes
dc.identifier.doi10.3928/1081597X-20230908-01es


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional